TABLE 64—AFFIRMATIVE HABITABILITY REQUIREMENTS

Inspectable Item Location Deficiency
Bathtub and Shower Unit Bathtub or shower cannot be used in private.
Cabinet and Storage Unit Food storage space is not present.
Carbon Monoxide Alarm Unit Carbon monoxide alarm is missing, not installed, or not installed in a proper location.
Carbon Monoxide Alarm Inside Carbon monoxide alarm is missing, not installed, or not installed in a proper location.
Cooking Appliance Unit Primary cooking appliance is missing.
Electrical GFCI Unit An unprotected outlet is present within six feet of a water source
Electrical GFCI Inside An unprotected outlet is present within six feet of a water source
Electrical GFCI Outside An unprotected outlet is present within six feet of a water source
Food Preparation Unit Food preparation area is not present.
Guardrail Unit Guardrail is missing or not installed.
Guardrail Inside Guardrail is missing or not installed.
Guardrail Outside Guardrail is missing or not installed.
HVAC Unit HVAC Not Working Between 10/1 and 3/31
HVAC Unit HVAC Not Working and Interior Temp is Less than 64
HVAC Inside HVAC Not Working Between 10/1 and 3/31
HVAC Inside HVAC Not Working and Interior Temp is Less than 64
HVAC Unit Unvented space heater that burns gas, oil, or kerosene is present.
HVAC Inside Unvented space heater that burns gas, oil, or kerosene is present.
Lighting Unit At least one (1) permanently installed light fixture is not present in the kitchen and bathroom.
Lighting Inside At least one (1) permanently installed light fixture is not present in the kitchen and bathroom.
Electrical Unit A habitable room does not have either two (2) working outlets or at least one (1) working outlet and one (1) permanently installed
Refrigerator Unit Refrigerator is missing.
Sink Unit Cannot activate or deactivate hot and cold water.
Sink Unit Sink is missing or not installed within the primary kitchen.
Smoke Alarm Unit Smoke alarm is not installed where required.
Smoke Alarm Inside Smoke alarm is not installed where required.
Toilet Unit Toilet cannot be used in private.