TABLE 64—AFFIRMATIVE HABITABILITY REQUIREMENTS
Inspectable Item | Location | Deficiency |
---|---|---|
Bathtub and Shower | Unit | Bathtub or shower cannot be used in private. |
Cabinet and Storage | Unit | Food storage space is not present. |
Carbon Monoxide Alarm | Unit | Carbon monoxide alarm is missing, not installed, or not installed in a proper location. |
Carbon Monoxide Alarm | Inside | Carbon monoxide alarm is missing, not installed, or not installed in a proper location. |
Cooking Appliance | Unit | Primary cooking appliance is missing. |
Electrical GFCI | Unit | An unprotected outlet is present within six feet of a water source |
Electrical GFCI | Inside | An unprotected outlet is present within six feet of a water source |
Electrical GFCI | Outside | An unprotected outlet is present within six feet of a water source |
Food Preparation | Unit | Food preparation area is not present. |
Guardrail | Unit | Guardrail is missing or not installed. |
Guardrail | Inside | Guardrail is missing or not installed. |
Guardrail | Outside | Guardrail is missing or not installed. |
HVAC | Unit | HVAC Not Working Between 10/1 and 3/31 |
HVAC | Unit | HVAC Not Working and Interior Temp is Less than 64 |
HVAC | Inside | HVAC Not Working Between 10/1 and 3/31 |
HVAC | Inside | HVAC Not Working and Interior Temp is Less than 64 |
HVAC | Unit | Unvented space heater that burns gas, oil, or kerosene is present. |
HVAC | Inside | Unvented space heater that burns gas, oil, or kerosene is present. |
Lighting | Unit | At least one (1) permanently installed light fixture is not present in the kitchen and bathroom. |
Lighting | Inside | At least one (1) permanently installed light fixture is not present in the kitchen and bathroom. |
Electrical | Unit | A habitable room does not have either two (2) working outlets or at least one (1) working outlet and one (1) permanently installed |
Refrigerator | Unit | Refrigerator is missing. |
Sink | Unit | Cannot activate or deactivate hot and cold water. |
Sink | Unit | Sink is missing or not installed within the primary kitchen. |
Smoke Alarm | Unit | Smoke alarm is not installed where required. |
Smoke Alarm | Inside | Smoke alarm is not installed where required. |
Toilet | Unit | Toilet cannot be used in private. |